80x120 Steel Aircraft Hangar
- Width
- 80 ft
- Length
- 120 ft
- Floor area
- 9,600 sq ft
- Perimeter
- 400 ft

Use
How a 80×120 Aircraft Hangar May Be Used
Door span
The clear door opening, not the footprint, is usually the governing dimension.
Tail height
Required clearance is set by the aircraft, and it drives eave and door height.
Maintenance area
Working space around the aircraft is planned separately from the parking envelope.
Apron access
Approach and taxi access affect where the opening is placed.
Example
Example Configuration

Quick dimensions
At a Glance
Width
80 ft across the gable end.
Length
120 ft along the sidewall.
Floor area
9,600 sq ft of clear floor.
Eave height
22 ft at the sidewall on the stored profile.
Configuration
How This Building Is Configured
Configuration summary
| Building type | Aircraft Hangar |
|---|---|
| Footprint | 80 ft × 120 ft |
| Floor area | 9,600 sq ft |
| Eave height | 22 ft |
Planning
Footprint & Space Planning
Footprint
Width and length are chosen together: width is usually fixed by what has to fit side by side, length by how many bays are needed.
Height
Eave height is commonly the governing dimension here, because clearance for the tallest item sets the door and the wall.
Access
Where vehicles and people enter changes the whole interior layout, so access is settled before anything else.
Doors and openings
Opening width, height and position are specified with the supplier; they affect the frame and the wall bracing.
Site
Slope, drainage, access for delivery and erection, and the foundation are confirmed for the actual property.
Expansion
Extending along the length is usually simpler than changing the width later, which is worth deciding up front.
Access
Doors & Access Considerations
Opening width
Across a 80 ft gable end, the practical opening width is limited by the frame and confirmed with the supplier.
Opening height
A 22 ft eave sets the ceiling on door height before any frame change.
Drive-through
Matching openings at both ends avoid reversing, at the cost of usable wall.
Similar sizes
Other Sizes for a Aircraft Hangar
80′ × 100′
8,000 sq ft
80′ × 140′
11,200 sq ft
70′ × 120′
8,400 sq ft
Related
Related Building Types

Helicopter Hangar
Explore
Clear Span Building
Explore
Commercial Building
Explore
Industrial Building
Explore
Example configuration — for planning purposes only.
FAQ
Common Questions
80 ft × 120 ft is 9,600 square feet of floor area before any interior partitions.
Length is usually adjusted in bay increments, and width is a larger design change. Both are confirmed with the supplier for the final design.
Site preparation, foundation and erection are commonly quoted separately from the building package. Confirm the scope of any quote you receive.
Compare nearby sizes
Related footprints for this building type
Each page works through one footprint for one building type.
Overview
A 80x120 aircraft hangar planned as a hangar sharing floor between an aircraft and ground vehicles or equipment
This page is ordered around rotation lane, because that is the decision this footprint settles first and every later choice follows from it.
The footprint holds 4 shared-use bays — 2 across by 2 deep — and leaves 24 feet of depth for a fixed vehicle bay along one wall, kept entirely outside the aircraft's swept path so the two never compete for the same floor at the same moment.
What distinguishes 80x120 is depth behaviour: 2 rows along 120 feet after 12 feet of circulation, with 24 feet unaccounted for at the end of the run. Service routes are cheap to plan now and expensive to retrofit through a finished shell.
A 80 by 120 footprint is a clearly directional plan: 9,600 sq ft enclosed by 400 ft of wall, at a 1.5:1 length-to-width proportion. Along its 120 ft dimension it takes 2 runs of shared-use bays at 42 ft, leaving 36 ft over — the 36 ft is where the argument about this size actually happens. Taken purely as arithmetic, 80 by 120 gives 1 shared-use bays across the 80 ft dimension once 12 ft is reserved for movement, and 2 deep along the 120 ft dimension. Run as a a hangar sharing floor between an aircraft and ground vehicles or equipment, 30 ft across is enough to be worth planning: a fixed vehicle bay along one wall, kept entirely outside the aircraft's swept path so the two never compete for the same floor at the same moment Extended maintenance work needs a defined place for removed components and documentation that is separate from the aircraft's own floor space.
This footprint is planned as a hangar sharing floor between an aircraft and ground vehicles or equipment. Spent as a square 98 by 98 instead, the same 9,600 sq ft would stand 2 shared-use bays across rather than 1, and would trade this plan's length for parallel access. That is the width-against-depth decision this footprint has already made. Compared with a 80 by 90 of the same width, the extra depth here adds run rather than reach: it buys about 2 shared-use bays in line, and every position past the second is retrieved by moving what stands in front of it. A building of this size behaves like a small yard under a roof: zones need to be defined, signed and left alone, or they migrate. The aircraft and the ground equipment are used on different schedules and by different logic, so the plan succeeds if either one can be moved without consulting the other's position first. Office, crew or administrative functions attached to a hangar are best consolidated into one enclosed wing rather than distributed across corners of the clear floor.
Areas, perimeter, roof area, ridge height, slab volume and the shared-use bay counts on this page are computed from the stored 80x120 record and this platform's planning module for the aircraft hangar category.
Usable area
How the 9,600 square feet divides at 80x120
Computed shared-use bay fit for a 80x120 aircraft hangar
| Measure | Computed at this footprint |
|---|---|
| Shared-use bays across the 80-foot width | 2 at a 38-foot module |
| Leftover width | 4 ft (480 sq ft as a full-length strip) |
| Rows along the 120-foot length | 2 at a 42-foot module after 12 ft of circulation |
| Leftover depth | 24 ft (1,920 sq ft across the width) |
| Total shared-use bays | 4 |
| Share of floor committed | 67% |
Module footprint used here is 38 by 42 feet, this platform's planning module for a aircraft hangar. It is not a code minimum or an engineered clearance.
Example allocation of the 120-foot length — planning model, not survey data
| Zone | Length along the building | Computed area |
|---|---|---|
| Aircraft parking area | 84 ft | 6,720 sq ft |
| Maintenance and equipment space | 24 ft | 1,920 sq ft |
| Office, parts and utility | 12 ft | 960 sq ft |
Shares applied to the stored 120-foot length; areas computed against the 80-foot width.
Module footprints and allocation shares come from this platform's use typology and are published as example planning models. They are not recommendations and do not describe a majority of projects.
Configurations
Configuring 4 shared-use bays at 80x120
The columns win at this footprint: 24-foot nominal bays against a 38-foot module means every layout decision starts from where the frames fall. A building that cannot be reversed out of is a building that gets used in one direction only.
Depth here creates a hierarchy: 2 rows means front positions get used and rear positions get filled. Deciding which is which up front is what keeps 80x120 workable. Noise from this floor reaches the office, the neighbours and the yard, and separation is a plan decision.
The straightforward addition is a lean-to or separate structure for the ground equipment, which returns the whole hangar floor to the aircraft and removes the daily negotiation between the two uses.
Configured as a hangar sharing floor between an aircraft and ground vehicles or equipment, 80x120 is judged on whether the 4 shared-use bays it holds match the operation, and on whether the 4 feet of spare width leaves the route this mode depends on.
- Does the work need racking or work zones on both sides with a full vehicle lane down the middle, or does it need a second lane that this 80-foot span cannot give?
- Is the 120-foot length being bought for depth, or for the repeated bays — a long repeating bay sequence, so segment boundaries are set by bay lines rather than by walls?
- Which aircraft dimension governs — wingspan at the opening or tail height?
- Which door system suits the operation, and has the end frame been designed for it?
Bay division shown here is a planning module computed from the stored length. Actual bay spacing is set by the manufacturer's frame design for the building.
Allocation
Dividing the floor for a hangar sharing floor between an aircraft and ground vehicles or equipment
The operation this hangar floor could equally be run as is a private hangar built around one owner's aircraft and personal storage: there is no side bay, so personal storage lines the same walls the aircraft has to clear on its way in and out. A fixed vehicle or equipment bay is set outside the aircraft's swept path from the moment the plan is drawn, rather than being wherever space happens to be left once the aircraft is positioned.
Because 24 feet clears the 12 feet this platform treats as usable, the end of the run is a room rather than a gap: 1,920 square feet for a fixed vehicle bay along one wall, kept entirely outside the aircraft's swept path so the two never compete for the same floor at the same moment. Every foot of width added multiplies through the roof and the frame; every foot of length mostly adds skin.
Spare width is the more valuable of the two leftovers here: a continuous 4-foot strip beats the same area stranded at the end of the run, because it touches every position along the way. Cleaning, maintenance and inspection all need reach, and reach is planned in the gaps rather than in the modules.
Spent as a square 98 by 98 instead, the same 9,600 sq ft would stand 2 shared-use bays across rather than 1, and would trade this plan's length for parallel access. That is the width-against-depth decision this footprint has already made. Compared with a 80 by 90 of the same width, the extra depth here adds run rather than reach: it buys about 2 shared-use bays in line, and every position past the second is retrieved by moving what stands in front of it. A building of this size behaves like a small yard under a roof: zones need to be defined, signed and left alone, or they migrate. The aircraft and the ground equipment are used on different schedules and by different logic, so the plan succeeds if either one can be moved without consulting the other's position first. Office, crew or administrative functions attached to a hangar are best consolidated into one enclosed wing rather than distributed across corners of the clear floor. That movement pattern, not the 9,600-square-foot total, is what decides whether the leftover 24 feet is useful here.
Openings
Openings for 2 shared-use bays across
One opening per position works on this gable: 2 across 80 feet, with 4 feet of wall to distribute as piers. Splitting that margin evenly is what keeps the elevation buildable. The count of working positions, not the headline area, is the figure that survives contact with the operation.
The 80 ft ends and the 120 ft sides offer very different opening budgets: 80 ft of end wall has room for one wide opening or two modest ones, while 120 ft of side wall can carry several without the openings competing. On this plan the deciding factor is whether mixed-use hangar planning or shared aircraft and vehicle floor should be the first thing reached from the door.
Framed-opening sizes, headers and the structure around them are engineered for the specific building. Confirm every opening with the door supplier and the building manufacturer before ordering.
Height
Interior height for a 80x120 aircraft hangar
Span drives headroom at 80x120: 80 feet of width on a 4:12 pitch puts 35.3 feet over the middle and 22 feet at the walls, so where a tall item stands matters as much as how tall it is. Temperature swing on a steel shell drives condensation decisions that outrank most layout preferences.
Clear height is set by the aircraft rather than the ground equipment, since equipment stored beside it rarely approaches the aircraft's own clearance needs.
Clear height below purlins, bracing and lighting is lower than the eave height. The usable figure comes from the manufacturer's framing for the selected building.
Comparison
What changes at adjacent footprints
Computed comparison of nearby footprints for a aircraft hangar
| Footprint | Floor area | Shared-use bays |
|---|---|---|
| 50x80 | 4,000 sq ft | 1 (1 x 1) |
| 40x100 | 4,000 sq ft | 2 (1 x 2) |
| 60x80 | 4,800 sq ft | 1 (1 x 1) |
| 40x120 | 4,800 sq ft | 2 (1 x 2) |
| 50x100 | 5,000 sq ft | 2 (1 x 2) |
Areas computed from each stored size record; shared-use bay counts computed with the same 38 by 42 foot planning module.
- 50x80 moves the count from 4 to 1 shared-use bays (1 across by 1 deep), which is the reason to choose between them.
- 40x100 moves the count from 4 to 2 shared-use bays (1 across by 2 deep), which is the reason to choose between them.
- 60x80 moves the count from 4 to 1 shared-use bays (1 across by 1 deep), which is the reason to choose between them.
Nearby footprints read for a aircraft hangar: exact change in area and in planning shared-use bays
| Footprint | Area Δ | % Δ | Shared-use bays at that footprint | What changes for this use |
|---|---|---|---|---|
| 100x100 | +400 sq ft | +4.2% | 2 (2 x 1) | −2 shared-use bays on the same planning module. |
| 60x150 | −600 sq ft | −6.2% | 3 (1 x 3) | −1 shared-use bay on the same planning module. |
| 80x100 | −1,600 sq ft | −16.7% | 1 (1 x 1) | −3 shared-use bays on the same planning module. |
| 80x150 | +2,400 sq ft | +25% | 2 (1 x 2) | −2 shared-use bays on the same planning module. |
Areas are arithmetic on two stored size records; shared-use bay counts use this platform's 38 by 42 foot planning module and are not a capacity statement.
Because this footprint is planned as a hangar sharing floor between an aircraft and ground vehicles or equipment, the useful next reads are different from the ones a differently shaped aircraft hangar suggests: mixed-use hangar planning, shared aircraft and vehicle floor, hangar vehicle bay.
Visualization
Reading the 80x120 footprint as a aircraft hangar
FAQ
Questions about 80x120 aircraft hangar projects
8,800 square feet of wall and 10,119 square feet of roof at a 4:12 pitch — the roof exceeding the floor by 5%.
Reserving 12 ft across the 80 ft dimension for movement leaves 68 ft of working width, which takes 1 shared-use bays at 38 ft. Along 120 ft it takes 2 runs at 42 ft. That is 2 positions out of 9,600 sq ft, and the remainder is circulation, walls and the margin every plan needs. Whether that count is enough depends on does the ground vehicle have a position it never has to vacate for the aircraft, or does the floor get renegotiated every time one of them arrives. These are planning figures computed from the footprint, not a quoted layout.
The width leaves 4 feet spare after 2 shared-use bays. That margin absorbs wall storage and passing room. Width is the dimension that cannot be extended later.
Not necessarily, but a separate smaller opening removes the dependency of the vehicle waiting behind the aircraft, or the reverse, at the single main door.
Length here buys 2 rows and 5 nominal bays; width buys 2 positions side by side. At this aspect ratio both dimensions are still adding usable positions.
Methodology
How this page was produced
Sources and methodology
Find Steel Buildings dimensional records
Find Steel Buildings · Primary platform dataset · Tier 1 — code authority, standards body, primary dataset or manufacturer engineering
Supports: Stored nominal width, length, eave height, roof pitch and slab thickness for this subject.
International Building Code and International Residential Code
International Code Council · Model code · Tier 1 — code authority, standards body, primary dataset or manufacturer engineering
Supports: The framework of adopted codes and local amendments that decides permitting, separation and opening requirements. Cited as the governing framework, never as a local requirement.
- Dimensional figures: Width, length, eave height, roof pitch and nominal slab thickness come from this platform's stored record for the subject. Floor area, perimeter, wall area, roof area, ridge height and slab volume are computed from those inputs rather than transcribed.
- Shared-use bay fit: Counts, leftover strips and per-module areas are computed from the stored 80x120 record against this platform's 38 by 42 foot planning module for the aircraft hangar category, with 12 feet allowed for circulation. The module is editorial planning typology, not a code minimum or an engineered clearance.
- Allocation model: Zone shares come from this platform's use typology for aircraft storage and maintenance and are applied arithmetically to the stored 120-foot length.
- Allocation and layout models: Layout splits are arithmetic on the stored footprint, published as example allocation models. They are not survey findings and do not describe what buyers most often choose.
- Clearance and opening guidance: Clearance and opening statements are planning guidance. Final dimensions depend on the selected door system, header detail and the manufacturer's engineering for the building.
Methodology notes
- Prices: No price figure appears on this page. Cost data is published on this platform only with a documented inclusion basis, a collection date and a named source.
Cost drivers
Quantities that move the estimate at 80x120
Quantities, not prices, are publishable here: roof cladding runs 10,119 square feet — 5% above the 9,600-square-foot floor at a 4:12 pitch — with 177.8 cubic yards of nominal slab beneath it. Access, not area, is what makes a plan feel small once it is in use.
Proportion drives cost here as much as size does: 400 ft of wall around 9,600 sq ft is 0.042 ft of wall per enclosed square foot, and a squarer plan of the same area would carry less. What moves the figure further on a a hangar sharing floor between an aircraft and ground vehicles or equipment is the fit-out mixed-use hangar planning implies, along with framed openings and the height chosen for the 80 ft span.
- the door system type, which drives the end-frame design
- the clear opening width and height the aircraft requires
- the eave height the door opening forces across the frame
- the apron outside the opening
Drawn to scale
Plans and dimensions
Every drawing below is generated from the exact dimensions for this building, so proportions and areas are accurate.