Skip to content
Find Steel Buildings

Building Types

40x70 Fire and EMS Station Building

Width
40 ft
Length
70 ft
Floor area
2,800 sq ft
Perimeter
220 ft
Concept visualization of a steel fire station at a representative 70 by 110 foot size; not a real project.
Example Configuration
steel fire station concept visualization at a representative 70x110 size.Example configuration — for planning purposes only
Last updated Aug 27, 2026Reviewed under the Find Steel Buildings editorial standards

Example

Example Configuration

Example configuration of a 40 by 70 foot fire and ems station building
Fire and EMS Station Building shown as an example configuration — for planning purposes only. Doors, colors and openings are specified for the actual project.

Get Quotes for a 40×70 Fire and EMS Station Building

Fire and EMS Station Building ✓40′ × 70′ ✓
Continue

Quick dimensions

At a Glance

  • Width

    40 ft across the gable end.

  • Length

    70 ft along the sidewall.

  • Floor area

    2,800 sq ft of clear floor.

  • Eave height

    14 ft at the sidewall on the stored profile.

Use

How a 40×70 Fire and EMS Station Building May Be Used

  • Assembly space

    Clear-span width determines how the main space can be arranged and seated.

  • Support rooms

    Ancillary rooms are commonly placed along one side or at one end.

  • Access and egress

    Entrance and exit placement follows the occupancy requirements for the use.

  • Acoustics and finish

    Interior treatment is specified with the intended activity in mind.

Configuration

How This Building Is Configured

70′ length40′ width2,800 sq ft
Footprint drawn to the stated dimensions.Platform calculation

Configuration summary

Building typeFire and EMS Station Building
Footprint40 ft × 70 ft
Floor area2,800 sq ft
Eave height14 ft

Planning

Footprint & Space Planning

  • Footprint

    Width and length are chosen together: width is usually fixed by what has to fit side by side, length by how many bays are needed.

  • Height

    Eave height affects door options, storage height and how open the interior feels.

  • Access

    Where vehicles and people enter changes the whole interior layout, so access is settled before anything else.

  • Doors and openings

    Opening width, height and position are specified with the supplier; they affect the frame and the wall bracing.

  • Site

    Slope, drainage, access for delivery and erection, and the foundation are confirmed for the actual property.

  • Expansion

    Extending along the length is usually simpler than changing the width later, which is worth deciding up front.

Access

Doors & Access Considerations

  • Opening width

    Across a 40 ft gable end, the practical opening width is limited by the frame and confirmed with the supplier.

  • Opening height

    A 14 ft eave sets the ceiling on door height before any frame change.

  • Drive-through

    Matching openings at both ends avoid reversing, at the cost of usable wall.

Similar sizes

Other Sizes for a Fire and EMS Station Building

Related

Related Building Types

FAQ

Common Questions

40 ft × 70 ft is 2,800 square feet of floor area before any interior partitions.

Length is usually adjusted in bay increments, and width is a larger design change. Both are confirmed with the supplier for the final design.

Site preparation, foundation and erection are commonly quoted separately from the building package. Confirm the scope of any quote you receive.

Compare nearby sizes

Related footprints for this building type

Each page works through one footprint for one building type.

Overview

A 40x70 fire and ems station building planned as a compact satellite substation extending coverage from a larger station without duplicating its full support functions

This page is ordered around through route, because that is the decision this footprint settles first and every later choice follows from it.

The footprint holds 4 coverage bays — 2 across by 2 deep — and the remaining 0 feet is marginal: there is no minimal crew space set aside, so any waiting or paperwork happens on the apparatus floor itself.

Commitment first: 64% of the 2,800 square feet goes to coverage bays at 450 square feet each, and 700 square feet survives as edge strip. A footprint is worth its own decision when that split lands where the work does. Noise from this floor reaches the office, the neighbours and the yard, and separation is a plan decision.

A 40 by 70 footprint is a clearly directional plan: 2,800 sq ft enclosed by 220 ft of wall, at a 1.8:1 length-to-width proportion. Along its 70 ft dimension it takes 2 runs of coverage bays at 30 ft, leaving 10 ft over — the 10 ft is where the argument about this size actually happens. A substation exists to extend geographic coverage, not to replicate everything the primary station offers, and the planning discipline is resisting the urge to add rooms that belong at the main station instead. The bay and a minimal support area are usually the whole program. Living quarters and the apparatus floor pull in opposite directions: one wants quiet separation, the other wants a short, direct route, and the plan has to hold both at once.

At 40x70 the operating question is a specific one: does this footprint deliberately do less than the main station, or is it quietly trying to duplicate the main station's full program at a smaller size? That is a different question from the one a fire and ems station building of another shape has to answer, and it is why this footprint is planned as a compact satellite substation extending coverage from a larger station without duplicating its full support functions rather than as generic covered area.

Planning assumptionPlatform calculation

Areas, perimeter, roof area, ridge height, slab volume and the coverage bay counts on this page are computed from the stored 40x70 record and this platform's planning module for the fire and ems station building category.

Height

Interior height for a 40x70 fire and ems station building

The stored configuration carries a 14-foot eave and computes to 19 feet at the ridge on a 3:12 pitch — a 5-foot rise across 40 feet. Height is therefore not uniform, and the sidewall is the constraint. Where the building sits on the site changes how much of this floor is genuinely reachable.

Height on a 40 ft span is a separate decision from the 70 ft length, and it is the span that sets the frame's behavior. Raising the eave over 2,800 sq ft affects every bay along the 70 ft dimension, so the test is whether satellite fire substation genuinely needs the extra clear height or only the floor area.

Ventilation across 2,800 square feet at this height: exhaust capture in the bays is planned as part of the building rather than added afterwards.

Planning assumptionPlanning guidance

Clear height below purlins, bracing and lighting is lower than the eave height. The usable figure comes from the manufacturer's framing for the selected building.

Usable area

How the 2,800 square feet divides at 40x70

Computed coverage bay fit for a 40x70 fire and ems station building

MeasureComputed at this footprint
Coverage bays across the 40-foot width2 at a 15-foot module
Leftover width10 ft (700 sq ft as a full-length strip)
Rows along the 70-foot length2 at a 30-foot module after 10 ft of circulation
Leftover depth0 ft (0 sq ft across the width)
Total coverage bays4
Share of floor committed64%

Module footprint used here is 15 by 30 feet, this platform's planning module for a fire and ems station building. It is not a code minimum or an engineered clearance.

Example allocation of the 70-foot length — planning model, not survey data

ZoneLength along the buildingComputed area
Primary operating area42 ft1,680 sq ft
Customer or staff area15.4 ft616 sq ft
Back of house and utility12.6 ft504 sq ft

Shares applied to the stored 70-foot length; areas computed against the 40-foot width.

Planning assumptionPlanning guidance

Module footprints and allocation shares come from this platform's use typology and are published as example planning models. They are not recommendations and do not describe a majority of projects.

Openings

Openings for 2 coverage bays across

The 40-foot gable can carry 2 openings, one per coverage bay, with 10 feet of wall left for piers between and beside them — the arrangement that keeps each position independently reachable. Snow, wind and site exposure change what this shape costs to build long before the interior plan does.

A single apparatus door sized to the housed apparatus and a personnel door are typically sufficient; the modest scale of this mode rarely justifies the dual-door drive-through arrangement used at higher-volume stations.

Planning assumptionEngineering-required

Framed-opening sizes, headers and the structure around them are engineered for the specific building. Confirm every opening with the door supplier and the building manufacturer before ordering.

Allocation

Dividing the floor for a compact satellite substation extending coverage from a larger station without duplicating its full support functions

The staffing and turnout pattern this station could equally be planned for is a continuously staffed station with living quarters separated from the apparatus floor: there is no buffer between quarters and the bay, so noise, exhaust and traffic from the apparatus floor reach the living space directly. Dividing the 2,800 sq ft by the 15 by 30 ft coverage bay gives roughly 4 positions before circulation is deducted a second time for cross movement. Whether the plan keeps 4 or drops to 2 comes back to the question this footprint is really answering: does this footprint deliberately do less than the main station, or is it quietly trying to duplicate the main station's full program at a smaller size?

Treating the last 0 feet as a room is the recurring planning error at 40x70: there is no minimal crew space set aside, so any waiting or paperwork happens on the apparatus floor itself. Temperature swing on a steel shell drives condensation decisions that outrank most layout preferences.

Spare width is the more valuable of the two leftovers here: a continuous 10-foot strip beats the same area stranded at the end of the run, because it touches every position along the way. The count of working positions, not the headline area, is the figure that survives contact with the operation.

Compared with a 40 by 50 of the same width, the extra depth here adds run rather than reach: it buys about 2 coverage bays in line, and every position past the second is retrieved by moving what stands in front of it. Spent as a square 53 by 53 instead, the same 2,800 sq ft would stand 2 coverage bays across rather than 2, and would trade this plan's length for parallel access. That is the width-against-depth decision this footprint has already made. At this scale the building is usually operated by one or two people who know where everything is, so the plan can be loose and the doors matter more than the divisions. Activity here is intermittent and brief compared with a primary station, so the building is planned around quick turnaround rather than sustained occupancy, and any function that requires sustained presence is usually better located at the primary station. A substation earns its size by doing deliberately less than a primary station, not by quietly duplicating the primary station's full program at a smaller footprint. That movement pattern, not the 2,800-square-foot total, is what decides whether the leftover 0 feet is useful here.

Primary operating area42 × 40 ft · 1,680 sq ftCustomer or staff area15.4 × 40 ft · 616 sq ftBack of house and utility12.6 × 40 ft · 504 sq ft70 ft overall length
operating and support allocation allocation across the 70-foot length

Configurations

Configuring 4 coverage bays at 40x70

At 23.3-foot nominal bays the structure works with the layout instead of against it: one coverage bay per bay line, walls free of awkward half-positions. Access, not area, is what makes a plan feel small once it is in use.

Depth here creates a hierarchy: 2 rows means front positions get used and rear positions get filled. Deciding which is which up front is what keeps 40x70 workable. Set the openings before the interior, because the openings cannot move and the interior can.

Extension is cheapest along the 70 ft dimension, where each added bay repeats work already framed; widening past 40 ft is a different frame rather than a longer one. Growing to 40 by 100 adds a 3th run of coverage bays — useful if the constraint is coverage bays rather than the 10 ft already spare at the far end.

Configured as a compact satellite substation extending coverage from a larger station without duplicating its full support functions, 40x70 is judged on whether the 4 coverage bays it holds match the operation, and on whether the 10 feet of spare width leaves the route this mode depends on.

  • Does the work need three parked lanes, or two lanes and a moving lane wide enough for equipment to pass, or does it need a second lane that this 40-foot span cannot give?
  • Is the 70-foot length being bought for depth, or for the repeated bays — six to eight repeated bays, and the bay line becomes the organising device for the whole plan?
  • Is the tallest apparatus dimension measured with everything mounted?
  • Drive-through or reverse-in, and what does the apron allow?
Planning assumptionTypical configuration

Bay division shown here is a planning module computed from the stored length. Actual bay spacing is set by the manufacturer's frame design for the building.

Cost drivers

Quantities that move the estimate at 40x70

No price appears on this page. The quantities that scale an estimate at 40x70 are 2,800 square feet of slab, 34.6 cubic yards of nominal concrete, 3,080 square feet of wall cladding and 2,886 square feet of roof cladding. Fire separation, egress and occupancy are determined for the specific building and can reshape this plan entirely.

The reduced support program is what keeps a substation smaller than a primary station of the same bay count; adding quarters, a full kitchen or training space here erodes that cost advantage without adding coverage.

  • apparatus door height and width
  • drive-through bays versus reverse-in bays
  • exhaust capture in the bays
  • crew quarters as a separate conditioned envelope
Why we don't quote thisWe do not state 40x70 fire and ems station building pricing here, because it varies too much to give an honest figure. Published only with a documented inclusion basis, a collection date and a named source.

Comparison

What changes at adjacent footprints

Computed comparison of nearby footprints for a fire and ems station building

FootprintFloor areaCoverage bays
30x401,200 sq ft2 (2 x 1)
24x501,200 sq ft0 (1 x 0)
32x401,280 sq ft0 (2 x 0)
36x401,440 sq ft0 (2 x 0)
24x601,440 sq ft1 (1 x 1)

Areas computed from each stored size record; coverage bay counts computed with the same 15 by 30 foot planning module.

  • 30x40 moves the count from 4 to 2 coverage bays (2 across by 1 deep), which is the reason to choose between them.
  • 24x50 moves the count from 4 to 0 coverage bays (1 across by 0 deep), which is the reason to choose between them.
  • 32x40 moves the count from 4 to 0 coverage bays (2 across by 0 deep), which is the reason to choose between them.

Nearby footprints read for a fire and ems station building: exact change in area and in planning coverage bays

FootprintArea Δ% ΔCoverage bays at that footprintWhat changes for this use
30x100+200 sq ft+7.1%1 (1 x 1)−3 coverage bays on the same planning module.
50x50−300 sq ft−10.7%3 (3 x 1)−1 coverage bay on the same planning module.
40x80+400 sq ft+14.3%2 (2 x 1)−2 coverage bays on the same planning module.
40x60−400 sq ft−14.3%2 (2 x 1)−2 coverage bays on the same planning module.

Areas are arithmetic on two stored size records; coverage bay counts use this platform's 15 by 30 foot planning module and are not a capacity statement.

Because this footprint is planned as a compact satellite substation extending coverage from a larger station without duplicating its full support functions, the useful next reads are different from the ones a differently shaped fire and ems station building suggests: satellite fire substation, coverage bay planning, minimal support station layout.

Visualization

Reading the 40x70 footprint as a fire and ems station building

70′ length40′ width2,800 sq ft
40x70 footprint plan, drawn from the stored dimensional record
12′ eave17′ ridge3:12 pitch · 40′ clear span
Gable cross section at a 14-foot eave and 3:12 pitch, computing to a 19-foot ridge

FAQ

Questions about 40x70 fire and ems station building projects

The width leaves 10 feet spare after 2 coverage bays. That margin absorbs wall storage and passing room. Width is the dimension that cannot be extended later.

Reserving 10 ft across the 40 ft dimension for movement leaves 30 ft of working width, which takes 2 coverage bays at 15 ft. Along 70 ft it takes 2 runs at 30 ft. That is 4 positions out of 2,800 sq ft, and the remainder is circulation, walls and the margin every plan needs. Whether that count is enough depends on does this footprint deliberately do less than the main station, or is it quietly trying to duplicate the main station's full program at a smaller size. These are planning figures computed from the footprint, not a quoted layout.

Length here buys 2 rows and 3 nominal bays; width buys 2 positions side by side. At this aspect ratio the building is already long for its span, so extra length adds depth rather than capacity.

Typically not at first; substations are usually planned for brief stays, with staffing patterns for the specific department determining whether that changes over time.

Bays are added in length; the door height established for the tallest apparatus effectively fixes the building Practically, the 70-foot dimension is the one that extends; the 40-foot span is fixed once the frames are set.

Methodology

How this page was produced

Sources and methodology

Verified sourceExternal factual sources
  • Find Steel Buildings dimensional records

    Find Steel Buildings · Primary platform dataset · Tier 1 — code authority, standards body, primary dataset or manufacturer engineering

    Supports: Stored nominal width, length, eave height, roof pitch and slab thickness for this subject.

  • International Building Code and International Residential Code

    International Code Council · Model code · Tier 1 — code authority, standards body, primary dataset or manufacturer engineering

    Supports: The framework of adopted codes and local amendments that decides permitting, separation and opening requirements. Cited as the governing framework, never as a local requirement.

Platform calculationComputed on this platform
  • Dimensional figures: Width, length, eave height, roof pitch and nominal slab thickness come from this platform's stored record for the subject. Floor area, perimeter, wall area, roof area, ridge height and slab volume are computed from those inputs rather than transcribed.
  • Coverage bay fit: Counts, leftover strips and per-module areas are computed from the stored 40x70 record against this platform's 15 by 30 foot planning module for the fire and ems station building category, with 10 feet allowed for circulation. The module is editorial planning typology, not a code minimum or an engineered clearance.
  • Allocation model: Zone shares come from this platform's use typology for commercial and customer-facing operations and are applied arithmetically to the stored 70-foot length.
Planning assumptionPlanning assumptions
  • Allocation and layout models: Layout splits are arithmetic on the stored footprint, published as example allocation models. They are not survey findings and do not describe what buyers most often choose.
  • Clearance and opening guidance: Clearance and opening statements are planning guidance. Final dimensions depend on the selected door system, header detail and the manufacturer's engineering for the building.

Methodology notes

  • Prices: No price figure appears on this page. Cost data is published on this platform only with a documented inclusion basis, a collection date and a named source.

Drawn to scale

Plans and dimensions

Every drawing below is generated from the exact dimensions for this building, so proportions and areas are accurate.

70′ length40′ width2,800 sq ft
Computed from stored dimensions
Footprint plan — 40′ × 70′, drawn to the stored dimensions.Platform calculation
Front third933 sq ftCenter third933 sq ftRear third933 sq ft40′ × 70′ floor plate
Computed from stored dimensions
Floor plate divided into equal thirds along the length; each area is computed from the stored footprint.Platform calculation

Compare 40x70 fire and ems station building configurations

Review the allocation models for this footprint side by side, then estimate the configuration you intend to build.

Get a Quote