Building Types
80x150 Distribution Center
- Width
- 80 ft
- Length
- 150 ft
- Floor area
- 12,000 sq ft
- Perimeter
- 460 ft

Quick dimensions
At a Glance
Width
80 ft across the gable end.
Length
150 ft along the sidewall.
Floor area
12,000 sq ft of clear floor.
Eave height
24 ft at the sidewall on the stored profile.
Configuration
How This Building Is Configured
Configuration summary
| Building type | Distribution Center |
|---|---|
| Footprint | 80 ft × 150 ft |
| Floor area | 12,000 sq ft |
| Eave height | 24 ft |
Planning
Footprint & Space Planning
Footprint
Width and length are chosen together: width is usually fixed by what has to fit side by side, length by how many bays are needed.
Height
Eave height is commonly the governing dimension here, because clearance for the tallest item sets the door and the wall.
Access
Where vehicles and people enter changes the whole interior layout, so access is settled before anything else.
Doors and openings
Opening width, height and position are specified with the supplier; they affect the frame and the wall bracing.
Site
Slope, drainage, access for delivery and erection, and the foundation are confirmed for the actual property.
Expansion
Extending along the length is usually simpler than changing the width later, which is worth deciding up front.
Use
How a 80×150 Distribution Center May Be Used
Logistics
Material entering one end and leaving the other is a common organising principle.
Fulfillment
Dock or grade-level door placement is usually decided before the frame layout.
Freight
Usable stacking height depends on eave height and any interior structure.
Example
Example Configuration

Access
Doors & Access Considerations
Opening width
Across a 80 ft gable end, the practical opening width is limited by the frame and confirmed with the supplier.
Opening height
A 24 ft eave sets the ceiling on door height before any frame change.
Drive-through
Matching openings at both ends avoid reversing, at the cost of usable wall.
Similar sizes
Other Sizes for a Distribution Center
80′ × 130′
10,400 sq ft
80′ × 170′
13,600 sq ft
70′ × 150′
10,500 sq ft
Related
Related Building Types

Warehouse
Explore
Industrial Building
Explore
Manufacturing Building
Explore
Commercial Building
Explore
Example configuration — for planning purposes only.
FAQ
Common Questions
80 ft × 150 ft is 12,000 square feet of floor area before any interior partitions.
Length is usually adjusted in bay increments, and width is a larger design change. Both are confirmed with the supplier for the final design.
Site preparation, foundation and erection are commonly quoted separately from the building package. Confirm the scope of any quote you receive.
Compare nearby sizes
Related footprints for this building type
Each page works through one footprint for one building type.
Overview
A 80x150 distribution center planned as a bulk floor holding full pallets in transit
This page is ordered around the working arrangement, because the 150-foot depth at 80x150 is what gives a distribution center its usable sequence of zones.
The footprint holds 15 pallet blocks — 5 across by 3 deep — and the remaining 12 feet is marginal: there is no internal receiving area, so checking happens in the aisle and put-away stops while it does.
What distinguishes 80x150 is depth behaviour: 3 rows along 150 feet after 18 feet of circulation, with 12 feet unaccounted for at the end of the run. A wider bay is a structural decision and a longer bay is a layout decision; the two are often confused.
A 80 by 150 footprint is a clearly directional plan: 12,000 sq ft enclosed by 460 ft of wall, at a 1.9:1 length-to-width proportion. Along its 150 ft dimension it takes 3 runs of pallet blocks at 40 ft, leaving 30 ft over — the 30 ft is where the argument about this size actually happens. Taken purely as arithmetic, 80 by 150 gives 4 pallet blocks across the 80 ft dimension once 18 ft is reserved for movement, and 3 deep along the 150 ft dimension. Run as a a bulk floor holding full pallets in transit, 6 ft across is below the 13 ft this use needs to be worth planning, so there is no internal receiving area, so checking happens in the aisle and put-away stops while it does Floor flatness for handling equipment is set at the pour and is difficult to correct afterwards.
At 80x150 the operating question is a specific one: can a full vehicle load be received, checked and put away without the floor stopping? That is a different question from the one a distribution center of another shape has to answer, and it is why this footprint is planned as a bulk floor holding full pallets in transit rather than as generic covered area.
Areas, perimeter, roof area, ridge height, slab volume and the pallet block counts on this page are computed from the stored 80x150 record and this platform's planning module for the distribution center category.
Configurations
Configuring 15 pallet blocks at 80x150
Nominal bay division computes to 6 bays at about 25 feet, wider than the 14-foot module — so a position can sit inside a bay without a frame line splitting it. Cleaning, maintenance and inspection all need reach, and reach is planned in the gaps rather than in the modules.
With 3 rows deep, the rear row is behind the front one. Without a route past it, those pallet blocks become storage positions rather than working ones — the real cost of depth at this width. A building that cannot be reversed out of is a building that gets used in one direction only.
Bulk floors extend away from the dock face, accepting longer travel, because the dock face is the constrained element and is rarely extendable.
Configured as a bulk floor holding full pallets in transit, 80x150 is judged on whether the 15 pallet blocks it holds match the operation, and on whether the 10 feet of spare width leaves the route this mode depends on.
- Does the work need racking or work zones on both sides with a full vehicle lane down the middle, or does it need a second lane that this 80-foot span cannot give?
- Is the 150-foot length being bought for depth, or for the repeated bays — a long repeating bay sequence, so segment boundaries are set by bay lines rather than by walls?
- How many docks does the throughput need, and does the yard support them?
- Is the staging depth in front of the docks protected from becoming storage?
Bay division shown here is a planning module computed from the stored length. Actual bay spacing is set by the manufacturer's frame design for the building.
Usable area
How the 12,000 square feet divides at 80x150
Computed pallet block fit for a 80x150 distribution center
| Measure | Computed at this footprint |
|---|---|
| Pallet blocks across the 80-foot width | 5 at a 14-foot module |
| Leftover width | 10 ft (1,500 sq ft as a full-length strip) |
| Rows along the 150-foot length | 3 at a 40-foot module after 18 ft of circulation |
| Leftover depth | 12 ft (960 sq ft across the width) |
| Total pallet blocks | 15 |
| Share of floor committed | 70% |
Module footprint used here is 14 by 40 feet, this platform's planning module for a distribution center. It is not a code minimum or an engineered clearance.
Example allocation of the 150-foot length — planning model, not survey data
| Zone | Length along the building | Computed area |
|---|---|---|
| Storage or unit area | 102 ft | 8,160 sq ft |
| Aisles and access | 36 ft | 2,880 sq ft |
| Office and utility | 12 ft | 960 sq ft |
Shares applied to the stored 150-foot length; areas computed against the 80-foot width.
Module footprints and allocation shares come from this platform's use typology and are published as example planning models. They are not recommendations and do not describe a majority of projects.
Allocation
Dividing the floor for a bulk floor holding full pallets in transit
The handling pattern this floor could equally be run as is a cross-dock floor where goods are sorted rather than stored: there is no marshalling depth, so goods are broken down in the lanes and the second face waits for the first. Dividing the 12,000 sq ft by the 14 by 40 ft pallet block gives roughly 12 positions before circulation is deducted a second time for cross movement. Whether the plan keeps 12 or drops to 9 comes back to the question this footprint is really answering: can a full vehicle load be received, checked and put away without the floor stopping?
There is no end zone at this footprint. 12 feet is circulation slack, not floor area with a purpose, and there is no internal receiving area, so checking happens in the aisle and put-away stops while it does. Service routes are cheap to plan now and expensive to retrofit through a finished shell.
The 10 feet of spare width runs the whole 150-foot length — 1,500 square feet of wall strip. It earns its keep as shelving, staging or a walking route, not as another pallet block. Every foot of width added multiplies through the roof and the frame; every foot of length mostly adds skin.
Units arrive in vehicle-sized batches and leave the same way, so peaks are large and infrequent rather than continuous. The floor has to absorb one whole load at a time without blocking the next. Slotting stock by movement rate saves more handling time than any single layout change. That movement pattern, not the 12,000-square-foot total, is what decides whether the leftover 12 feet is useful here.
Height
Interior height for a 80x150 distribution center
Span drives headroom at 80x150: 80 feet of width on a 4:12 pitch puts 37.3 feet over the middle and 24 feet at the walls, so where a tall item stands matters as much as how tall it is. Noise from this floor reaches the office, the neighbours and the yard, and separation is a plan decision.
Height on a 80 ft span is a separate decision from the 150 ft length, and it is the span that sets the frame's behavior. Raising the eave over 12,000 sq ft affects every bay along the 150 ft dimension, so the test is whether bulk storage planning genuinely needs the extra clear height or only the floor area.
Clear height below purlins, bracing and lighting is lower than the eave height. The usable figure comes from the manufacturer's framing for the selected building.
Openings
Openings for 5 pallet blocks across
One opening per position works on this gable: 5 across 80 feet, with 10 feet of wall to distribute as piers. Splitting that margin evenly is what keeps the elevation buildable. Temperature swing on a steel shell drives condensation decisions that outrank most layout preferences.
Dock openings sized to the vehicles served, with enough of them that a slow unload does not stop the next arrival. Two openings and a queue are usually better than one opening and a yard.
Dock-height handling at fixed positions, with staging depth in front of every dock that cannot be borrowed for storage.
Framed-opening sizes, headers and the structure around them are engineered for the specific building. Confirm every opening with the door supplier and the building manufacturer before ordering.
Cost drivers
Quantities that move the estimate at 80x150
No price appears on this page. The quantities that scale an estimate at 80x150 are 12,000 square feet of slab, 222.2 cubic yards of nominal concrete, 11,040 square feet of wall cladding and 12,649 square feet of roof cladding. The count of working positions, not the headline area, is the figure that survives contact with the operation.
Slab specification and dock provision carry the estimate; block storage needs no racking, which is why the floor itself has to be right.
- the number of dock openings and their equipment
- clear height for racking
- floor area committed to staging rather than storage
- yard area for trailer manoeuvring
Comparison
What changes at adjacent footprints
Computed comparison of nearby footprints for a distribution center
| Footprint | Floor area | Pallet blocks |
|---|---|---|
| 60x80 | 4,800 sq ft | 6 (6 x 1) |
| 40x120 | 4,800 sq ft | 8 (4 x 2) |
| 50x100 | 5,000 sq ft | 10 (5 x 2) |
| 60x100 | 6,000 sq ft | 12 (6 x 2) |
| 50x120 | 6,000 sq ft | 12 (4 x 3) |
Areas computed from each stored size record; pallet block counts computed with the same 14 by 40 foot planning module.
- 60x80 moves the count from 15 to 6 pallet blocks (6 across by 1 deep), which is the reason to choose between them.
- 40x120 moves the count from 15 to 8 pallet blocks (4 across by 2 deep), which is the reason to choose between them.
- 50x100 moves the count from 15 to 10 pallet blocks (5 across by 2 deep), which is the reason to choose between them.
Nearby footprints read for a distribution center: exact change in area and in planning pallet blocks
| Footprint | Area Δ | % Δ | Pallet blocks at that footprint | What changes for this use |
|---|---|---|---|---|
| 100x100 | −2,000 sq ft | −16.7% | 14 (7 x 2) | −1 pallet block on the same planning module. |
| 80x120 | −2,400 sq ft | −20% | 10 (5 x 2) | −5 pallet blocks on the same planning module. |
| 100x150 | +3,000 sq ft | +25% | 12 (6 x 2) | −3 pallet blocks on the same planning module. |
| 60x150 | −3,000 sq ft | −25% | 20 (5 x 4) | +5 pallet blocks on the same planning module. |
Areas are arithmetic on two stored size records; pallet block counts use this platform's 14 by 40 foot planning module and are not a capacity statement.
Because this footprint is planned as a bulk floor holding full pallets in transit, the useful next reads are different from the ones a differently shaped distribution center suggests: bulk storage planning, receiving area planning, dock provision.
Visualization
Reading the 80x150 footprint as a distribution center
FAQ
Questions about 80x150 distribution center projects
Not enough for a planned room at this footprint: there is no internal receiving area, so checking happens in the aisle and put-away stops while it does.
Reserving 18 ft across the 80 ft dimension for movement leaves 62 ft of working width, which takes 4 pallet blocks at 14 ft. Along 150 ft it takes 3 runs at 40 ft. That is 12 positions out of 12,000 sq ft, and the remainder is circulation, walls and the margin every plan needs. Whether that count is enough depends on can a full vehicle load be received, checked and put away without the floor stopping. These are planning figures computed from the footprint, not a quoted layout.
It depends on racking height plus the lift's reach and the clearance above the top pallet. The stored configuration computes to 37.3 feet at the ridge, but the eave is the number that governs anything standing near a wall.
Enough for one complete vehicle load, laid out and checkable. Less than that means checking happens in the traffic route.
The footprint holds 15 pallet blocks — 5 across by 3 deep — and the remaining 12 feet is marginal: there is no internal receiving area, so checking happens in the aisle and put-away stops while it does. Those counts use a 14 by 40 foot planning module with 18 feet allowed for circulation, so a different module changes the answer.
Methodology
How this page was produced
Sources and methodology
Find Steel Buildings dimensional records
Find Steel Buildings · Primary platform dataset · Tier 1 — code authority, standards body, primary dataset or manufacturer engineering
Supports: Stored nominal width, length, eave height, roof pitch and slab thickness for this subject.
International Building Code and International Residential Code
International Code Council · Model code · Tier 1 — code authority, standards body, primary dataset or manufacturer engineering
Supports: The framework of adopted codes and local amendments that decides permitting, separation and opening requirements. Cited as the governing framework, never as a local requirement.
- Dimensional figures: Width, length, eave height, roof pitch and nominal slab thickness come from this platform's stored record for the subject. Floor area, perimeter, wall area, roof area, ridge height and slab volume are computed from those inputs rather than transcribed.
- Pallet block fit: Counts, leftover strips and per-module areas are computed from the stored 80x150 record against this platform's 14 by 40 foot planning module for the distribution center category, with 18 feet allowed for circulation. The module is editorial planning typology, not a code minimum or an engineered clearance.
- Allocation model: Zone shares come from this platform's use typology for storage and warehousing and are applied arithmetically to the stored 150-foot length.
- Allocation and layout models: Layout splits are arithmetic on the stored footprint, published as example allocation models. They are not survey findings and do not describe what buyers most often choose.
- Clearance and opening guidance: Clearance and opening statements are planning guidance. Final dimensions depend on the selected door system, header detail and the manufacturer's engineering for the building.
Methodology notes
- Prices: No price figure appears on this page. Cost data is published on this platform only with a documented inclusion basis, a collection date and a named source.
Drawn to scale
Plans and dimensions
Every drawing below is generated from the exact dimensions for this building, so proportions and areas are accurate.
Compare 80x150 distribution center configurations
Review the allocation models for this footprint side by side, then estimate the configuration you intend to build.